NIT_97650
Working out relay settings and preparing coordination curves of Schneider make Relays at 1x120 MW IEL-Jamshedpur Site A) Machine parameters are as follows : Rating : 825 KW, 6.6kV Application : Induced Draft Fan Motor type : Induction Motor B) Relay parameters are as follows : Make : Schneider Relay-1 (in Incomer VCB, Q1) : P3U30 (Feeder Protection Relay) Relay-2 (in Bypass VCB, Q3) : P3U30 (Motor Protection Relay) C) Requirements : (i) Relay settings for 2 nos. relays (ii) e-TAP studies for VFD incomer breaker (inrush current) (ii) e-TAP studies for Motor Starting, running conditions along with coordination curves
| NIT NO. |
NIT_97650
|
|---|---|
| UNIT NAME |
BHEL, PSER
|
| ADDRESS |
Bharat Heavy Electricals Limited,
1X120MW,IEL(TATA),PH#7, CPP Project, Opposite Sakchi Thana, Jamshedpur, Dist.: East Singhbhum, Jharkhand – 831001 |
|
ssdas@bhel.in,abhaya.dash@bhel.in,smohanty@bhel.in
|
|
| TELEPHONE NO. |
91-9438183646
|
| FAX NO. | -- |
| APPROVED BY | Construction Manager, BHEL, IEL-Jamshedpur Site , Construction Manager, BHEL, IEL-Jamshedpur Site |
| CONTACT PERSON | SOURAV SAGAR DAS |
| NOTIFICATION NO. |
BHEL: PSER:IEL-JSR: ELEC: NIT/26/01
|
| PUBLISH DATE | 07-02-2026 |
| TENDER TITLE | Working out relay settings and preparing coordination curves of Schneider make Relays at 1x120 MW IEL-Jamshedpur Site A) Machine parameters are as follows : Rating : 825 KW, 6.6kV Application : Induced Draft Fan Motor type : Induction Motor B) Relay parameters are as follows : Make : Schneider Relay-1 (in Incomer VCB, Q1) : P3U30 (Feeder Protection Relay) Relay-2 (in Bypass VCB, Q3) : P3U30 (Motor Protection Relay) C) Requirements : (i) Relay settings for 2 nos. relays (ii) e-TAP studies for VFD incomer breaker (inrush current) (ii) e-TAP studies for Motor Starting, running conditions along with coordination curves |
| TENDER TYPE |
Work Contract
|
| TENDER DESCRIPTION | Working out relay settings and preparing coordination curves of Schneider make Relays at 1x120 MW IEL-Jamshedpur Site A) Machine parameters are as follows : Rating : 825 KW, 6.6kV Application : Induced Draft Fan Motor type : Induction Motor B) Relay parameters are as follows : Make : Schneider Relay-1 (in Incomer VCB, Q1) : P3U30 (Feeder Protection Relay) Relay-2 (in Bypass VCB, Q3) : P3U30 (Motor Protection Relay) C) Requirements : (i) Relay settings for 2 nos. relays (ii) e-TAP studies for VFD incomer breaker (inrush current) (ii) e-TAP studies for Motor Starting, running conditions along with coordination curves |
| TENDER VALUE |
-
|
| DOCUMENT VALUE |
0
|
| DATE OF NOTIFICATION | 07-02-2026 01:16:05 PM |
| CLOSING DATE OF SALE FROM | 09-02-2026 03:00:00 PM |
| CLOSING DATE OF SUBMISSION FORM | 09-02-2026 03:01:00 PM |
| TENDER OPENING DATE | 09-02-2026 04:00:00 PM |
| Download Full Details of Tender |
Important links of tender
Tender Classification
Back to previous page | Page last updated date : 07-02-2026