भारत हेवी इलेक्ट्रिकल्स लिमिटेड की आधिकारिक वेबसाइट, नई दिल्ली, भारत का लोगो
  • मुख्य पृष्ठ
  • Package –I: Removal/Repair of defective furnace upper side (left, right and front) & intermediate fin weld panels and erection, testing and commi...

NIT_82426

यह पृष्ठ हिंदी में उपलब्ध नहीं है, कृपया अंग्रेजी में पढ़ने के लिए नीचे दिये गए लिंक पर क्लिक करें

Package –I: Removal/Repair of defective furnace upper side (left, right and front) & intermediate fin weld panels and erection, testing and commissioning of newly supplied of same items along with accessories & hydro test of these new panels with connected other related circuits of Boiler including alignment, testing & welding / NDT of newly erected panels at Unit#7, 2X660MW RRUVNL, Suratgarh Super Thermal Power Plant, Dist.-Sri Ganganagar, Rajasthan. Package –II: Removal/Repair of defective furnace fin water wall (WW) / steam cooled wall (SCW) weld panels as directed by Engineer-in charge and erection, testing and commissioning of newly supplied of same items along with accessories & hydro test of these new panels with connected other related circuits of Boiler including alignment, testing & welding / NDT of newly erected panels at Unit#8, 2X660MW RRUVNL, Suratgarh Super Thermal Power Plant, Dist.-Sri Ganganagar, Rajasthan (exact details of faulty water wall / steam cooled wall panels will be provided during execution).